Part Number Hot Search : 
SED1330 BF39933 00950 B380C NLAS1053 IN4732 R1003 AM79C03
Product Description
Full Text Search
 

To Download GPFM600-24 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  112 condor d.c. power supplies, inc., 2311 statham parkway, oxnard, ca 93033 800-235-5929 ? 805-486-4565  fax 805-487-8911  www.condorpower.com gpfm600 medical 600 watt global performance switchers ac input 85-264 vac, 47-63 hz single phase. output power continuous output power, 600 watts. hold-uptime 20 ms minimum from loss of ac input until output reaches 3% below nominal. line and load regulation 1% over the entire input voltage and frequency range, and over the entire output current range. minimum load no minimum load required. overload protection current limit 105% minimum, 125% maximum of the specified full load current. output noise 50 mv pk-pk maximum. transient response maximum of 5% change in vout for a load change of 1.25 a. recovers to 1% within 500u sec. overvoltage protection built in on all models. ovp crowbar reduces output voltage below nominal rating in less than 50 ms. output voltage decay is dependent upon loading. dc power good optocoupler isolated output indicates that the dc output is equal to or greater than 21.6 (-0 + 0.25) volts. this signal shall be driven when in the active ?dc good? state. efficiency minimum of 75% under full load and input of 120 vac 60 hz. inrush current limit inrush current to 125% of maximum operating current. turn on time of the power supply not to exceed 3 seconds over the full input voltage and frequency range. emi/emc compliance all models include built-in emi filtering to meet emissions requirements: emi specifications compliance level conducted emissions en55011 class b; fcc class b static discharge en61000-4-2, 6 kv contact, 8 kv air rf field susceptibility en61000-4-3, 3 v/meter fast transients/bursts en61000-4-4, 2 kv, 5 khz surge susceptibility en61000-4-5, 1 kv diff., 2 kv com. vibration and shock all models are to meet mil-std 810e, method 514.4 category. environmental designed for 0 to 60c operation at full rated output power; derate output current and total output power by 2.5% per c above 50c. medical leakage current 150 a under normal conditions. maximum under single fault conditions, 250 a. patient sink leakage with 120 vac, 60 hz applied to any output with respect to the chassis will be less than 500 a. medical safety agency approved to ul2601-1, en60601-1-2, csa c22.2 no. 601.1.2. specifications:  small package (12.00? x 5.50? x 3.09?)  power factor corrected to en61000-3-2 class a  full load rating to 60c  85 to 264 vac input  medically approved to ul2601-1, iec601-1, csa c22.2 no. 601.1.2  2 year warranty  features: marked to lvd
113 condor d.c. power supplies, inc., 2311 statham parkway, oxnard, ca 93033 800-235-5929  805-486-4565  fax 805-487-8911  www.condorpower.com gpfm600 medical 600 watt global performance switchers l e d o m l a i c r e m m o c t u p t u o t u p t u o ) a ( m u m i x a m t n i o p t e s p v o n o i t a l u g e r l a t o t p - p e s i o n 4 2 - 0 0 6 m f p gc a v 4 2a 5 2v 6 . 0 8 . 5 2% 1v m 0 0 1 gpfm600 mechanical specifications dimensions: inches millimeters input: j1 molex p/n 43160-31-3 pin 1: ac line pin 2: ac neutral pin 3: earth ground output: j2 molex p.n. 39-29-1147 14 pin right angle header pin 1: +24 v pin 2: +24 v pin 3: +24 v return pin 4: +24 v return pin 5: n/a pin 6: ac good pin 7: ac good return pin 8: +24 v pin 9: +24 v pin 10: +24 v return pin 11: +24 v return pin 12: n/a pin 13: dc good pin 14: dc good return a. units should be allowed to warm up/operate under non-condensing conditions before application of power. cooling provided by internal fan ? heatsink temperatures should not exceed 90 o c for extended periods in the installation. b. random vibration ? 10 to 2000hz, 6db/octave roll-off from 350 to 2000hz, 3 orthogonal axes. tested for 10 min./axis operating and 1 hr./axis non-operating. c. shock testing ? half-sinusoidal, 10 3 ms duration, direction, 3 orthogonal axes, total 6 shocks. l a t n e m n o r i v n e n o i t a c i f i c e p s g n i t a r e p o g n i t a r e p o - n o n ) a ( e r u t a r e p m e tc o 0 6 o t 0c o 0 6 + o t 8 1 - ) a ( y t i d i m u hh r % 7 9 o t 0h r % 7 9 o t 0 ) b ( k c o h sg 0 2 k p g 0 4 k p e d u t i t l at f 0 0 0 , 0 1 o t 0 0 5 -t f 0 0 0 , 0 4 o t 0 0 5 - ) c ( n o i t a r b i vg 5 . 1 s m r g 3 0 0 . 0 , 2 z h / g 5 s m r 6 2 0 . 0 , g 2 z h /


▲Up To Search▲   

 
Price & Availability of GPFM600-24

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X